Effect of air intake temperatures on the air-water harvester performance

dc.contributor.authorMirmanto, M.
dc.contributor.authorNurpatria, N.
dc.contributor.authorHendra, J.K.
dc.date.accessioned2024-03-18T06:55:24Z
dc.date.available2024-03-18T06:55:24Z
dc.date.issued2024
dc.description.abstractDuring the dry season, some parts of Indonesia experience drought and a clean water crisis, resulting in scarcity and difficulty in drinking water. One of the solutions to solve this problem is to use an air-water harvester machine that produces water from the air. Since the intake air temperature affected the water yield, the article examined the relationship between the engine intake air temperature and the machine’s performance. The study aimed to determine the performance of the air-water harvester machine at various air intake temperatures. The research was carried out experimentally for a refrigerant working fluid R134a. The rotary-type 1/4 PK compressor was used to realize the research. The air temperatures entering the condensing unit varied between 30, 35, and 40 °C. The results showed that the highest average water mass obtained was 0.34 kg at a temperature variation of 30 °C. The highest total heat absorbed by the condensing unit from the air of 184 W occurred at a temperature variation of 40 °C. Overall, an increase in the air intake temperatures allowed for a decrease in the performance of the air-water harvester machine by more than 5 %.en_US
dc.identifier.citationMirmanto M., Nurpatria N., Hendra J. K. (2024). Effect of air intake temperatures on the air-water harvester performance. Journal of Engineering Sciences (Ukraine), Vol. 11(1), pp. G1–G8. https://doi.org/10.21272/jes.2024.11(1).g1en_US
dc.identifier.urihttps://essuir.sumdu.edu.ua/handle/123456789/95005
dc.language.isoenen_US
dc.publisherSumy State Universityen_US
dc.rights.uriccbync4en_US
dc.subjectenergy efficiencyen_US
dc.subjectclean water and sanitationen_US
dc.subjectprocess innovationen_US
dc.subjectair intake temperatureen_US
dc.subjectheat transferen_US
dc.titleEffect of air intake temperatures on the air-water harvester performanceen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Mirmanto_jes_1_2024.pdf
Size:
631.37 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.96 KB
Format:
Item-specific license agreed upon to submission
Description: